Routine

Tracheostomy decannulation

Decannulation · Critical Care
Physician-written · Verified by three sets of doctors · Reviewed November 2026

Bedside summary

Structured removal of a tracheostomy once the airway and secretions are safely manageable, reducing complications and readmission.

Assessment

Investigations

  • Cough strength and secretion burden
  • Cuff deflation tolerance
  • Capping or speaking valve trial tolerance
  • Swallow assessment

Management

  • Confirm resolution of the original indication
  • Deflate the cuff and assess upper-airway patency
  • Trial a speaking valve then capping
  • Downsize the tube if needed
  • Remove the tube once capping tolerated and secretions low
  • Apply an occlusive stoma dressing and monitor
  • Keep reinsertion equipment nearby for 24-48 h

Drugs & doses

—

Disposition

Ward or ICU step-down; monitor after decannulation.

Failed capping or weak cough defers decannulation.

Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.