PEEP — positive end-expiratory pressure
PEEP · Critical Care / ICU
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
PEEP prevents alveoli returning to atmospheric pressure in expiration: recruits collapsed alveoli, redistributes lung water, raises FRC and improves oxygenation — at the cost of reduced venous return/preload and raised RV afterload. Intrinsic PEEP (auto-PEEP) arises from insufficient expiratory time with air-trapping.
Red flags
- High PEEP + hypovolaemia = profound hypotension
- Air-trapping in asthma/COPD — keep set PEEP below PEEPi and lengthen expiration
Management
- Indications: hypoxaemia needing high FiO₂, severe respiratory failure (pressure–volume optimisation), cardiogenic pulmonary oedema (also improves cardiac output), high-PEEPi weaning
- Adjust in 3–5 cmH₂O steps; re-check gases and haemodynamics after 15–30 min
- A practical scale: FiO₂ 0.3→PEEP 5 rising stepwise to FiO₂ 1.0→PEEP 18+ (ARDSNet tables)
- “Best PEEP”: the lowest PEEP achieving SaO₂ ≥90% at an acceptable FiO₂ without haemodynamic compromise
- Falling BP after PEEP increase → volume load ± inotrope, or step back down
Exam pearls
- Physiological PEEP (~2–3 cmH₂O from the closed larynx) is lost after intubation
- PEEP may INCREASE cardiac output in left heart failure — the failing LV loves reduced preload/afterload
Titrate PEEP to oxygenation AND haemodynamics — the best number is patient-specific.
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.