Patient-ventilator dyssynchrony

Dyssynchrony · Critical Care
Physician-written · Verified by three sets of doctors · Reviewed November 2026

Bedside summary

Mismatch between patient effort and ventilator delivery raises work of breathing, worsens gas exchange and prolongs ventilation. Recognising the pattern on waveforms guides correction.

Assessment

Investigations

  • Pressure, flow and volume waveform inspection
  • Assess sedation depth and pain
  • ABG and auto-PEEP measurement
  • Exclude secretions and bronchospasm

Management

  • Identify the type: ineffective triggering, double-triggering, flow or cycle asynchrony
  • Treat pain and optimise comfort before deepening sedation
  • Adjust trigger sensitivity and rise time
  • Match inspiratory time and flow to demand
  • Reduce auto-PEEP by lowering rate or extending expiration
  • Reassess waveforms after each change

Drugs & doses

Analgesia titrated to comfort
Short-acting sedation if needed

Disposition

ICU; recurrent dyssynchrony prompts mode review.

Waveform analysis is the bedside diagnostic tool; treat cause before paralysing.