Urgent

Passive leg raise & dynamic fluid responsiveness

Preload test · Critical Care
Physician-written · Verified by three sets of doctors · Reviewed November 2026

Bedside summary

A passive leg raise mimics a reversible fluid bolus, predicting whether more fluid will raise cardiac output and avoiding harmful over-resuscitation.

Assessment

Investigations

  • Real-time cardiac output or velocity-time integral monitor
  • Pulse pressure or stroke volume variation
  • Baseline MAP and lactate
  • End-expiratory occlusion where available

Management

  • Start semi-recumbent, then lower trunk and raise legs to 45 degrees
  • Measure cardiac output change within 60-90 s
  • A rise of >=10% predicts fluid responsiveness
  • If responsive and hypoperfused, give a measured fluid bolus
  • If non-responsive, switch to vasopressors or inotropes
  • Reassess after each intervention

Drugs & doses

Balanced crystalloid: 250-500 mL bolus if responsive

Disposition

ICU; repeat as haemodynamics evolve.

Dynamic indices outperform static CVP for predicting fluid response.

Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.