Passive leg raise & dynamic fluid responsiveness
Preload test · Critical Care
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
A passive leg raise mimics a reversible fluid bolus, predicting whether more fluid will raise cardiac output and avoiding harmful over-resuscitation.
Assessment
Investigations
- Real-time cardiac output or velocity-time integral monitor
- Pulse pressure or stroke volume variation
- Baseline MAP and lactate
- End-expiratory occlusion where available
Management
- Start semi-recumbent, then lower trunk and raise legs to 45 degrees
- Measure cardiac output change within 60-90 s
- A rise of >=10% predicts fluid responsiveness
- If responsive and hypoperfused, give a measured fluid bolus
- If non-responsive, switch to vasopressors or inotropes
- Reassess after each intervention
Drugs & doses
Balanced crystalloid: 250-500 mL bolus if responsive
Disposition
ICU; repeat as haemodynamics evolve.
Dynamic indices outperform static CVP for predicting fluid response.
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.