Bedside summary
Adjust in response to blood gases, oximetry/capnography, patient comfort, and weaning progress. Re-examine the patient and check tube position before every change.
Red flags
- Sudden deterioration after adjustment — think tube migration, pneumothorax, or circuit problem before blaming the disease
- High airway pressures with falling BP — tension pneumothorax or breath-stacking
Management
- Low PaO₂: raise FiO₂; raise PEEP (watch pressures and cardiac output); lengthen I:E; raise pressure-control/support or VT; consider deeper sedation ± relaxants, prone positioning, inhaled vasodilator; or accept permissive hypoxaemia
- High PaO₂: lower FiO₂ first, then PEEP/I:E
- High PaCO₂: raise rate or VT (pressure allowing); reduce dead space; consider permissive hypercapnia; reduce rate if air-trapping (intrinsic PEEP)
- Low PaCO₂: reduce rate and/or VT
- After every change: re-check gases and haemodynamics in 20–30 min
Exam pearls
- “Migration” of the ET tube into a main bronchus mimics worsening disease — check depth at the teeth and breath sounds
- Permissive hypercapnia is acceptable in ARDS/asthma if pH tolerated — the lungs matter more than the number
One change at a time; reassess; treat pressure alarms as diagnoses waiting to be made.