Urgent

Pacemaker / ICD emergency

Device · Cardiac
Physician-written · Verified by three sets of doctors · Reviewed November 2026

Management

  • 12-lead ECG and device interrogation early — most answers live in the device
  • Bradycardia with failure to capture → treat as bradycardia; transcutaneous pacing if compromised
  • Recurrent ICD shocks: magnet over the device inhibits further shocks (pacing unaffected)
  • Treat the arrhythmia driving the shocks — amiodarone, sedation, correct K⁺/Mg²⁺
  • Electrical storm (≥3 shocks/24 h) → ICU, beta-blockade, cardiology now
  • Examine the pocket — infection or erosion needs urgent device-team review

Drugs & doses

Magnet for inappropriate shocks
Amiodarone for storm

Disposition

Cardiology/device clinic urgently; ICU for electrical storm.

A ring magnet stops inappropriate ICD shocks instantly — know where yours lives in resus.

Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.