Sudden loss of the capnograph trace

Flat ETCO2 · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026

Bedside summary

A sudden flat capnograph has three broad causes — the patient has no circulation, no ventilation, or the sampling equipment has failed. It must be treated as cardiac arrest until circulation is confirmed.

Assessment

Investigations

  • Feel a central pulse immediately
  • Check for disconnection, oesophageal tube or airway obstruction
  • Inspect sampling line for water/kinking and the module for failure
  • SpO2 and ECG
  • Confirm chest movement and breath sounds

Management

  • Feel a central (carotid/femoral) pulse at once
  • If no pulse, start CPR and follow the cardiac arrest algorithm
  • If pulse present, exclude ventilation failure: disconnection, obstruction, oesophageal intubation, severe bronchospasm
  • Switch to hand ventilation with 100 percent oxygen
  • If ventilation is adequate and pulse present, suspect sampling-line or monitor fault
  • Replace sampling line or module and cross-check with a second monitor

Drugs & doses

100 percent oxygen
Adrenaline 1 mg IV per ALS algorithm if cardiac arrest confirmed

Disposition

Depends on cause — arrest call vs equipment swap.

Low rather than absent ETCO2 with ongoing CPR may indicate inadequate compressions or return of spontaneous circulation — use the waveform, not just the number.