Standard anaesthetic monitoring set-up
Monitoring · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
Establishing the minimum monitoring required before inducing anaesthesia, present continuously until recovery. These standards underpin the early detection of every critical incident.
Assessment
Investigations
- Pulse oximeter function
- Non-invasive blood pressure and ECG
- Capnography and agent analyser
- Airway pressure and disconnection alarms
- Nerve stimulator and temperature probe availability
Management
- Attach the monitor and confirm all alarms are active before induction
- Apply pulse oximetry and ECG
- Set non-invasive blood pressure to cycle appropriately
- Connect capnography before airway instrumentation
- Enable the oxygen analyser and agent monitor
- Add neuromuscular and depth monitoring when a relaxant or TIVA is used
- Place a temperature probe for cases over 30 minutes
- Never leave an anaesthetised patient unattended
Drugs & doses
—
Disposition
Continues from induction to recovery handover.
AAGBI standards: pulse oximetry, capnography, ECG, blood pressure, agent and oxygen analysis are mandatory (AAGBI minimum monitoring).