Second-generation supraglottic airway — insertion and conduct
SGA · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
A cuffed perilaryngeal device with a gastric drain channel used for airway maintenance in suitable elective cases. Second-generation devices allow higher seal pressures and gastric access.
Assessment
Investigations
- Suitability (fasting, low aspiration risk, body habitus)
- Correct size by weight
- Seal and leak assessment after insertion
- Gastric port patency
- Positive-pressure requirement
Management
- Select size by weight and check the cuff
- Achieve adequate depth of anaesthesia
- Insert along the palate until resistance
- Inflate the cuff to 60 cmH2O or less
- Confirm ventilation and a square capnograph trace
- Pass a gastric tube through the drain channel
- Secure the device and support with a bite block
- Convert to a tracheal tube if the seal is inadequate
Drugs & doses
Propofol: 2-3 mg/kg IV (deeper than for intubation)
Fentanyl: 1 microgram/kg IV to obtund response
No routine neuromuscular blocker required
Disposition
Recovery; remove awake or deep per protocol.
Keep cuff pressure at or below 60 cmH2O to limit pharyngeal morbidity (AAGBI).
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.