Operating theatre fire safety
Theatre safety · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
Surgical fires arise when the fire triad of oxidiser, fuel and ignition source coincides, especially during airway or head-and-neck surgery with diathermy or laser in an oxygen-enriched field.
Assessment
Investigations
- Identify high-risk cases (airway/head-and-neck with diathermy/laser)
- Oxidiser concentration in the surgical field
- Alcohol-based prep drying time
- Availability of saline and a fire plan
- Laser-safe tube for airway laser surgery
Management
- Assess fire risk before high-risk surgery
- Minimise the inspired oxygen concentration in the field
- Avoid nitrous oxide which also supports combustion
- Allow alcohol-based skin prep to dry fully
- Use a laser-resistant tube for airway laser surgery
- Keep saline and a fire plan immediately available
- If an airway fire occurs, stop gases, remove the tube and flood with saline, then re-establish the airway
Drugs & doses
No drugs — safety procedure
Flood an airway fire with saline/water
Re-establish the airway and ventilate after extinguishing
Disposition
Theatre; manage any burn injury and debrief.
Reduce the oxidiser, separate ignition from fuel and, for an airway fire, stop gases and remove the burning tube immediately (AAGBI/APSF fire safety).