One-lung ventilation - lung isolation technique
Lung isolation · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
Lung isolation separates the two lungs to allow single-lung ventilation for thoracic surgery or to protect one lung from contamination. The choice is between a double-lumen tube and a bronchial blocker, with position always confirmed by fibreoptic bronchoscopy.
Assessment
Investigations
- Chest imaging and bronchoscopy to assess airway anatomy and side of surgery
- Measure the trachea/bronchi for tube sizing; review for distorted anatomy or stents
- ABG and ventilation parameters baseline
Management
- Choose the device: left double-lumen tube for most cases, bronchial blocker if difficult airway or need for postoperative ventilation
- Size and place the tube; a left DLT is sited with the bronchial lumen in the left main bronchus
- Confirm position by fibreoptic bronchoscopy after placement and again after turning the patient
- Initiate OLV with protective settings and 100% oxygen initially, then titrate FiO2
- Clamp/deflate to isolate the operative lung and verify collapse with the surgeon
- Troubleshoot malposition promptly if airway pressures rise or oxygenation falls
- At the end, suction, re-expand both lungs and plan extubation or tube exchange
Drugs & doses
Double-lumen tube (left 37-39 Fr female, 39-41 Fr male) or bronchial blocker
Protective OLV: Vt 4-6 mL/kg, PEEP 5 cmH2O, plateau <25-30 cmH2O
Lidocaine spray to larynx to blunt response during placement
Disposition
Theatre; convert to single-lumen tube if postoperative ventilation needed.
Always verify lung isolation with the fibreoptic bronchoscope after placing the tube and again after repositioning the patient.
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.