Low-flow & minimal-flow anaesthesia
Circle technique · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
A circle-system technique using fresh gas flows below 1 L/min (minimal flow below 0.5 L/min) to conserve volatile agent, warm and humidify gases and reduce theatre pollution.
Assessment
Investigations
- Inspired and expired oxygen (FiO2) continuously
- Agent analyser for inspired and end-tidal volatile
- Capnography and soda lime colour/temperature
- SpO2
- Circuit integrity and gas sampling line
Management
- Denitrogenate with high flows for the first few minutes
- Reduce fresh gas flow once uptake has fallen
- Increase the delivered (dial) volatile to offset dilution
- Monitor FiO2 continuously to prevent a hypoxic mixture
- Watch soda lime for exhaustion and heat (compound A/CO)
- Increase flows transiently to change depth quickly
- Return to higher flows for emergence and washout
Drugs & doses
Fresh gas flow below 1 L/min (minimal flow below 0.5 L/min)
Keep inspired oxygen above a safe minimum (commonly 30%+)
Higher dialled volatile compensates for the lower flow
Disposition
Theatre; requires continuous FiO2 and agent monitoring.
Safe only with continuous oxygen and agent analysis; accumulation of compound A, CO and nitrogen is the main hazard (Morgan).