A circle-system technique using fresh gas flows below 1 L/min (minimal flow below 0.5 L/min) to conserve volatile agent, warm and humidify gases and reduce theatre pollution.

Assessment

Investigations

  • Inspired and expired oxygen (FiO2) continuously
  • Agent analyser for inspired and end-tidal volatile
  • Capnography and soda lime colour/temperature
  • SpO2
  • Circuit integrity and gas sampling line

Management

  • Denitrogenate with high flows for the first few minutes
  • Reduce fresh gas flow once uptake has fallen
  • Increase the delivered (dial) volatile to offset dilution
  • Monitor FiO2 continuously to prevent a hypoxic mixture
  • Watch soda lime for exhaustion and heat (compound A/CO)
  • Increase flows transiently to change depth quickly
  • Return to higher flows for emergence and washout

Drugs & doses

Fresh gas flow below 1 L/min (minimal flow below 0.5 L/min)
Keep inspired oxygen above a safe minimum (commonly 30%+)
Higher dialled volatile compensates for the lower flow

Disposition

Theatre; requires continuous FiO2 and agent monitoring.

Safe only with continuous oxygen and agent analysis; accumulation of compound A, CO and nitrogen is the main hazard (Morgan).