Endotracheal tube obstruction under anaesthesia

Blocked tube · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026

Bedside summary

The tracheal tube can obstruct from kinking, biting, secretions, blood, a herniated cuff or a foreign body, causing rising pressure and falling tidal volume. Rapid exclusion then tube change restores ventilation.

Assessment

Investigations

  • Capnography (attenuated or absent trace)
  • Pass a suction catheter to test and clear the lumen
  • Inspect for kinking, biting and cuff herniation
  • SpO2 and airway pressures
  • Fibreoptic inspection if available

Management

  • Call for help and give 100 percent oxygen
  • Hand ventilate to assess resistance
  • Insert a bite block if the patient is biting the tube
  • Pass a suction catheter; if it will not pass, the tube is obstructed
  • Deflate the cuff in case of cuff herniation
  • If ventilation remains impossible, remove and replace the tube or re-oxygenate by facemask/supraglottic device
  • Use a tube exchanger or re-laryngoscopy for the replacement

Drugs & doses

100 percent oxygen
Propofol: 0.5-1 mg/kg IV to deepen before tube change
Suxamethonium 1 mg/kg or rocuronium 1 mg/kg if relaxation needed

Disposition

Continue once a patent airway is confirmed by capnography.

Inability to pass a suction catheter is the quickest bedside confirmation of tube obstruction — do not hesitate to remove a tube you cannot ventilate through.

Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.