Bronchial blocker placement
Blocker · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
An inflatable balloon advanced through or alongside a single-lumen tube to isolate a lobe or lung. Preferred where a double-lumen tube is impractical, such as a difficult airway or paediatric patient.
Assessment
Investigations
- Indication and need for selective lobar isolation
- Single-lumen tube size for coaxial passage
- Fibreoptic bronchoscope availability
- Baseline oxygenation
- Planned side of surgery
Management
- Intubate with a single-lumen tube of adequate size
- Pass the blocker through the multiport adaptor
- Advance into the target bronchus under fibreoptic vision
- Inflate the balloon (usually 4-8 mL) to achieve seal
- Confirm isolation and lung collapse bronchoscopically
- Open the central channel to speed deflation and suction
- re-check position after patient positioning
- Deflate to restore two-lung ventilation at closure
Drugs & doses
Propofol: 1.5-2.5 mg/kg IV
Rocuronium: 0.6-1 mg/kg IV
Remifentanil: TCI 3-5 ng/mL
Disposition
Theatre; confirm position after repositioning.
Bronchial blockers allow selective lobar isolation and suit the difficult airway (Miller 9e).