Anaesthesia for rigid bronchoscopy
Rigid bronchoscopy · Anaesthesia & Perioperative
Physician-written · Verified by three sets of doctors · Reviewed November 2026
Bedside summary
Rigid bronchoscopy is a shared, open airway used for foreign body removal, tumour debulking, stenting and massive haemoptysis. Ventilation competes with the surgeon for the airway, so a clear plan for oxygenation (jet, apnoeic or spontaneous) and a smooth technique are essential.
Assessment
Investigations
- Chest radiograph/CT, review of the lesion and airway anatomy
- ABG, ECG, FBC, coagulation and crossmatch if haemoptysis
- Assessment for critical airway narrowing
Management
- Agree the ventilation strategy with the surgeon: Venturi (jet) ventilation, apnoeic oxygenation or spontaneous ventilation
- Use total intravenous anaesthesia for stable depth during an open airway
- Obtund airway reflexes with topical lidocaine and remifentanil to prevent coughing and movement
- Paralyse for jet ventilation; deliver jets down the bronchoscope watching chest rise and allowing full expiration (barotrauma risk)
- Monitor oxygenation closely; be ready to ventilate by facemask or tube between instrumentations
- Manage haemorrhage, airway soiling and loss of airway as emergencies
- Recover with the airway protected and observe for stridor and bleeding
Drugs & doses
Propofol TCI (3-6 micrograms/mL) and remifentanil TCI (4-8 ng/mL) TIVA
Rocuronium 0.6-1 mg/kg (reverse with sugammadex)
Topical lidocaine up to 3 mg/kg to airway
Jet ventilation via Sanders injector; allow expiration to avoid breath-stacking
Disposition
Recovery; ICU/HDU if airway compromise or bleeding.
With jet ventilation, always allow full passive expiration between jets to avoid dynamic hyperinflation and barotrauma in an open airway.
Disclaimer: Educational decision support for qualified clinicians and students — not a substitute for clinical judgement, local protocols or a full drug reference. Confirm every dose and contraindication against your formulary before prescribing.